SKU
084H4532
Brand:

084H4532 Danfoss Level Sensor, AKS 4100U Coaxial version, 45 insertion length with LCD display/interface unit

Level Sensor - AKS 4100U Coaxial version, 45" insertion length with LCD display/interface unit
List Price $4,529.48 List Price $4,529.48 Web Price $3,066.11
Estimate shipping for this product
Details
The AKS 4100/4100U liquid level sensor is designed specifically to measure liquid levels in a wide range of refrigeration applications. The AKS 4100/4100U liquid level sensor is based on a proven techhology called Time Domain Reflectometry (TDR) or Guided Micro Wave. AKS 4100/4100U liquid level sensor can be used to measure the liquid level of many different refrigerants in vessels, accumulators, receivers, standpipes, etc. The electrical output is a 2-wired, loop powered 4 - 20 mA output signal, which is proportional to the refrigerant liquid level. AKS 4100/4100U in a cable version is suitable for HCFC, Non flammable HFC and R717 (Ammonia), and differing lengths from 800 mm / 31.5 in. and up to 5000 mm / 197 in.. The coaxial version of AKS 4100/4100U is designed for use with R744 (CO2), HCFC, Non flammable HFC and R717 (Ammonia). The AKS 4100/4100U coaxial version should always be used for marine applications for all refrigerant types. The AKS 4100/4100U cable version should NOT be used for CO2 or marine applications. Dust, foam, vapour, agitated surfaces, boiling surfaces, changes in density or in the dielectric constant , ?r, for the liquid have no influence on the AKS 4100/4100U performance. Oil accumulated in the bottom of a standpipe will not disturb the liquid level signal and it is not necessary to remove AKS 4100/4100U for cleaning after oil has been drained out of the standpipe.
More Information
More Information
Weight 8.400000
Condition New
Manufacturer Danfoss
Minimum Temperature Range C -60 °C
Minimum Temperature Range F -76 °F
Maximum Temperature Range F 212 °F
Maximum Temperature Range C 100 °C
Minimum Ambient Temperature (C) -40 °C
Minimum Ambient Temperature (F) -40 °F
Maximum Ambient Temperature (C) 80 °C
Maximum Ambient Temperature (F) 176 °F
Maximum Working Pressure (PSIG) 1450 psig
Maximum Working Pressure (BAR) 100 bar
GTIN 5702428453233
Resources
LLS-1
(Size: 8.3 MB)
LLS-2
(Size: 262.1 KB)
Reviews